DSC PC1832 - Help
Changing and Adding User Codes:
PC 1555, PC 5010, PC 1616, PC 1832, PC 1864
Master Code: To program the master code, enter [*][5][current master code][40][new master code]. The master
code must be four digits long. Press [#] to return to the ready state.
Additional Codes: Up to 32 additional access codes may be programmed.
Duress is user # 33
Program New Codes
Enter [*][5][master code][code number 01-32][new access code]. The code number is a double digit number for 01-
32. Access codes must be four digits. Enter digits 0-9 only. Press [#] to return to the ready state.
Erase a Code
Enter [*][5][master code][code number 01-32][*]. Press the [#] to return to the ready state.
The master code cannot be erased.
Resetting Clock (Loss of System Time and Date)
To reset press [*] [6], then the Master Code, then [1]. Enter the time in military (24hr) format 00:00 to 23:59. Then,
enter date as MM DD YY, then #.
Ex. (time) 10:00 am is 1000 2:30 pm is 1430
Reset Battery:
Arm and then disarm the system. It may take a few minutes.
Bypassing Zone:
PC 1555, PC 5010, PC 1616, PC 1832, PC 1864
Press the * button then 1, then two digit zone number, then #.
Reset Smoke Detector:
PC 1555, PC 5010, PC 1616, PC 1832, PC 1864
Press [*] [7] [2]